• Provide Support to Alabama Power Company on SF6 equipment, • Purchase SF6 Breakers, 15 kV to 500 kV • Manage Alabama Power Company spare SF6 breaker fleet • Provide support to Alabama Power Company's Substation Maintenance groups, Substation support group, Substation Construction, Safety and Training organizations

[email protected]
News Detail
  • Do’s and Don’ts of SF6 Gas Handling

    May 28, 2014 · purity, moisture and acids to address safety concerns. Do not intentionally “sniff” SF 6 to check for a faulted condition SF 6 must be reclaimed –Do not vent to the atmosphere Moisture in SF 6 combined with switching could produce harmful acids –Do perform routine moisture measurements.

    Get Price
  • Handling and Use of Sulfur Hexafluoride Gas

    • Substation Construction • General Construction Maintenance III. POLICY A. Sulfur Hexafluoride Gas Clean SF 6 gas is an inert, stable, colorless, odorless, nontoxic, nonflammable gas. It is approximately five times heavier than air and will displace air in confined areas. SF 6 gas contains no oxygen and will not support life.

    Get Price
  • SF6 Gas Decomposed! Best handling practices APC

    • Provide Support to Alabama Power Company on SF6 equipment, • Purchase SF6 Breakers, 15 kV to 500 kV • Manage Alabama Power Company spare SF6 breaker fleet • Provide support to Alabama Power Company’s Substation Maintenance groups, Substation support group, Substation Construction, Safety and Training organizations

    Get Price
  • Sulfur Hexafluoride SF6 Safety Data Sheet SDS P4657

    7.1. Precautions for safe handling Precautions for safe handling : Wear leather safety gloves and safety shoes when handling cylinders. Protect cylinders from physical damage; do not drag, roll, slide or drop. While moving cylinder, always keep in place removable valve cover. Never attempt to lift a cylinder by its cap; the cap is intended solely to

    Get Price
  • National Grid begins journey to SF6-free HV substations

    solutions on their networks, and many others are now considering the new GE solution. The environmental argument for g3 is staggering SF6 remains in the atmosphere for 3200 years, and its concentration has increased by 20 % in the past 5 years alone. The time for change has come. Now there is an alternative

    Get Price
  • Safety in Substations and Switchyards Training Course

    Identify special precautions necessary when working with capacitor banks and current transformers. Chemical Safety. Identify chemical hazards that may exist in substations and switchyards. Describe safety precautions applicable to working with insulating oil. Describe safety precautions applicable to working with SF6 gas and nitrogen gas. Personal Safety

    Get Price
  • SF6 Gas Properties - sayedsaad.com

    SF6 Safety precautions: Today there is no known dielectric and breaking agent combined better than SF6 gas. Initial state. In its initial state, before it has undergone thermal stress (usually the electric arc); SF6 is perfectly safe in normal conditions: - It is non-toxic, - It is uninflammable, - It will not explode.

    Get Price
  • SF6 properties, and use in MV and HV switchgear

    6 - insulated substation, ordered by EDF and put into service in the Paris region in 1966. c 1967: the FA circuit-breaker was launched and progressively replaced the compressed air equipment which had established its position in France and elsewhere during the previous 25 years. c 1971: changes in the needs of the industry led

    Get Price
  • Myth About SF6 Gas In Electrical Equipment

    May 25, 2020 · Buildings containing SF6-filled indoor equipment should be provided with ventilation; natural ventilation would normally be adequate to prevent the accumulation of SF6 released due to leakage (see IEC 61634, sub-clause 3.4: “Safety of personnel” and IEC 61936-1). Type and extent of required measures depend upon location of the room, the accessibility, and the ratio of gas to room volume.

    Get Price
  • Substation Maintenance and Construction Manual Circuit

    table of contents (continued) pacific gas and electric company substation maintenance and construction manual circuit breakers booklet

    Get Price
  • Gas-Insulated Substations - GIS - Electrical Engineering Portal

    Best practices and the personnel safety aspects of SF6 gas handling are covered in international standards (IEC, 1995). Moisture The SF6 in the equipment must be dry enough to avoid condensation of moisture as a liquid on the surfaces of the solid epoxy support insulators because liquid water on the surface can cause a dielectric breakdown.

    Get Price
  • SF6 (GIS) gas insulated substation Manufacturer in China

    The SF6 gas insulated substation (GIS) is assembled by several SF6 gas insulated switchgear configurations in an outdoor enclosure which could reach IP54 protection grade. With the advantage of SF6 gas insulating ability (the interrupting arcs capability is 100 times more than air), gas insulated substation could operate in stable condition for more than 30 years.

    Get Price
  • Safety in Substations and Switchyards - Instant Video

    Chemical Safety – 7 minutes Identifies chemical hazards that may exist in substations and switchyards. Describes safety precautions applicable to working with insulating oil, both PCB-free and PCB-contaminated. Describes safety precautions applicable to working with insulating (SF6) gas and sealing (nitrogen) gas.

    Get Price
  • 6 Basic Rules to Ensure Substation Safety - the Elecectricity

    Rule No. 6, GROUNDING; All substation metallic structures, fences, and equipment tanks should be connected to a station ground grid which should be designed to ensure that step and touch potential values are lower than the ones stipulated in the applicable standards.

    Get Price
  • Substation Maintenance Troubleshooting of Switchgears SF6

    4.1 SF6 Gas Properties. 4.2 SF6 Metal Enclosed Switchgear. 4.3 SF6 Apparatus and Components. 4.4 SF6 Circuit Breakers. 4.5 Insulation Coordination and Over voltage protection. 4.6 Handling, Maintenance, Inspection and Testing. 4.7 General Design Considerations. 4.8 SF6 Troubleshooting

    Get Price
  • Green Gas for Grid - g3 - SF6 Free Solutions

    SF 6 SF6 (or Sulphur Hexafluoride) had been the standard gas used inside high voltage electrical equipment as an insulating and arc-quenching medium. However, SF 6 SF6 is also listed as an extremely potent greenhouse gas according to the Kyoto protocol, with 23,500 times the comparative Global Warming Potential of CO 2 and a lifetime of 3,200 years in the atmosphere.

    Get Price
  • White paper Three keys to designing safe, reliable and

    of environmental and safety disasters for decades beyond the initial commissioning of the project. Here are the three key principles heavy industrial users should consider when designing their substations: − Select the proper substation configuration − Engineer substations for safety − Build reliability into the substation design White paper

    Get Price
  • PGE Phases Out SF6 in HV Substation GIS | TD World

    The utility’s first purchase of a dry-air/vacuum GIS was for its Evolution substation at the Livermore, California, U.S., training center. Most recently, the utility purchased a second dry-air/vacuum GIS for a 115-kV, 50-kA, 3000-A multi-bay GIS at its new Hunters Point substation.

    Get Price
  • Safety In Substations And Switchyards Training Video

    Identify chemical hazards that may exist in substations and switchyards. Describe safety precautions applicable to working with insulating oil, both PCH-free and PCB-contaminated. Describe safety precautions applicable to working with insulating (SF6) gas and sealing (nitrogen) gas. Describe safety precautions applicable to working with battery banks.

    Get Price
  • Good Industry ‘Best Practice ’ Safety Co -ordinator Guide

    guaranteed safety precautions that are being held between two sa fety co - ordinators from two different companies. Safety Document: A safety document of a design that is used to guarantee safety precautions, namely a Sanction or a Permit. Sanction: A company specific safety document that allows work/ testing removal of earthing devices.

    Get Price
  • SF6 Breaker Testing And Maintenance - Industrial Tests

    Spotless Safety Record for all employees; About SF6 Circuit Breakers. SF6 electrical circuit breaker is a device where a current is operating with SF6 or Sulphur Hexafluoride being carried on its contacts. It breaks off the power when there’s an excessive electricity supply that exceeds the allowed voltage to prevent circuit overload.

    Get Price
  • Safe Work Practices on High Voltage Substation Apparatus

    This document supports the Power System Safety Rules (PSSR) and its requirements assembled under ‘High Voltage Substation Apparatus Category 5. The document describes safe work practices for the control of hazardous situations. The following block diagram shows the location of this document in relation to other Power System Safety Rules

    Get Price
  • Use and handling of sulphur hexafluoride (SF

    Substation Maintenance Instruction SMI 119 – Transmission and zone substation data entry, asset structure and details Electrical Safety Rules Network Management Plan (December 2013 Review) Electricity Supply Act 1995 (as amended) Occupational Health and Safety Act 2000

    Get Price
  • MiniSub - Liquid Filled - Power Systems Technology

    SF6 quality and stability are maintained by use of totally sealed tank construction, an internal purifying absorbent and the extremely fast Arc Whipper® interrupter. A color coded, field replaceable pressure gauge and self-sealing fill valve allow monitoring and addition of SF6 as necessary.

    Get Price
  • SF6: Does its Impact Outweigh its Benefits? | TD World

    Powerplant and substation electrical staff are very familiar with sulfur hexafluoride or SF6 which is a common insulating gas used in electrical equipment like electrical switches and circuit breakers. For many decades, SF6 has been the go-to dielectric insulating material for high-voltage electrical systems installed in enclosed spaces.

    Get Price
  • SF6 Gas Properties and Handling - Instant Video – Alexander

    Summary. Sulfur hexafluoride (SF6) gas has been used for limited applications in electrical equipment for many years. Recently, it has gained increased use as a dielectric and arc quenching medium in a variety of high-voltage applications, including circuit breakers, load-break switches, and substation buses. If SF6 is not handled properly, its dielectric properties can be compromised, which can result in equipment failures.

    Get Price
  • Rules to Follow For Substation Safety - LinkedIn

    Feb 29, 2016 · Our customers for substation safety equipment regularly pose questions relating to safety protection during substation operation and maintenance. There are a number of hazards unique to substations.

    Get Price
  • SF6 (SULFUR HEXAFLOURIDE) APPLICATION IN GAS INSULSATED

    A gas insulated substation (GIS) uses a superior dielectric gas, SF6, at moderate pressure for phase to phase and phase-to-ground insulation. The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in SF6 gas inside grounded metal enclosures.

    Get Price
  • SF6 Gas Insulated Substations (GIS)|Khobar|Riyadh|Jeddah

    A GIS results in the lower overall project cost GIS is the more economical solution. GIS has all live parts contained in SF6 gas-light enclosures. The bus bars are physically arranged in trefoil formation largely to cancel out the resultant stray magnetic field and any associated enclosure eddy current losses.